Our Products
ECK 1800-Me

Type of refrigerant
R134a
Service procedure
Fully automatic or manual
Voltage
220-240V 50/60 Hz
Scale resolution
10 g
Oil scale resolution
5 g
Working temperature range
11/49°C
Filter system
1 filter for humidity
Vacuum pump
72 litre/min capacity, 0.1 mbar vacuum level
Compressor
1/3 HP
Recovery speed
300 g/min in liquid phase
Refrigerant bottle
12 litres, refillable
Hoses
3 metres
Overall size
55 x 60 x 105 cm
Weight
80 kg
Pressure gauges
Class 1
Bottle pressure gauge
Class 2.5
Bottle heater Option

STANDARD FEATURES

Refrigerant Management
Each service is saved in station memory, offering the option of creating a customised archive of all refrigerant transactions.

Automatic Leak Testing
The station checks for leaks during the vacuum phase. If leaks are found, it interrupts operation and gives an alarm.

Coated PCB board
Protected against high humidity environmental conditions.

Compressor
specifically designed to work with high temperatures


Patent pending

OPTIONS

Thermal Printer
For a complete, detailed report.
Automatic Bottle Heater
For fast recharging at high or low ambient temperatures.